Dust Collection Equipment

CCJ/A Type Wet Dust Remover Assembly

The CCJ/A Type Wet Dust Remover Assembly collects airborne dust from crushing, screening and conveying operations in mineral processing plants. It uses water to capture particles through inertial impact and scrubbing, then discharges clean air. The unit installs downstream of dust sources and upstream of the exhaust stack.

01Model/Associated Data
02CCJ/A-5
03CCJ/A-7
04CCJ/A-10
05CCJ/A-14
06CCJ/A-20
07CCJ/A-30

Technical parameters

Suited to sticky or abrasive dusts that blind fabric filters, it reduces maintenance in wet environments. Xinhai supplies it with matched blowers and pumps for simpler integration.

The parameter table covers the CCJ/A series, from smaller units for isolated sources to large assemblies for centralised systems. Key variables include equipment resistance, purification efficiency and ventilator type. Larger models accommodate higher gas flow rates with proportionally greater resistance; efficiency stays consistent across the range. The model code (e.g., XW1/1) identifies the ventilator and assembly configuration.

CCJ/A Type Wet Dust Remover Assembly technical parameters, 15 models
Model/Associated DataCCJ/A-5CCJ/A-7CCJ/A-10CCJ/A-14CCJ/A-20CCJ/A-30CCJ/A-40CCJ/A-60
Dust CollectorAir Volume ( m^3/h )50007000100001400020000300004000060000
Equipment Resistance (Pa)1000-1200
Purification Efficiency %>97
Ventilator4-72-II Type VentilatorModel4A4.5A5A6C8C8C10C12C
Speed (r/min)29002900290022401600180012501120
Air Volume ( m^3/h )4020-74205730-105807950-1472011900-1710017920-3100020100-3480034800-5015053800-77500
Total Pressure (Pa)2040-13402580-17003240-22402720-22902520-18803180-24103180-24102770-2190
MotorModelY132S1-2Y132S2-2Y160M2-2Y180M-4Y180M-2Y200L2-2Y225M-4Y280S-4
Power (kW)5.57.51518.522375575
Water ConsumptionEvaporation (kg/h)17.524.5354975105140210
Overflow (kg/h)15021030042060090012001800
Bottom Flow (kg/h)42560286012001700255034005100
Flushing Volume ( m3 )0.480.661.041.21.72.53.45
Unit Weight (kg)791956119624263277395549896765
RemarksThe power of the solenoid valve used in the automatic water level control system is 80 VA.
CCJ/A Type Wet Dust Remover Assembly, continued (10 rows)
ModelXW1/1XW1/2XW1/3XW1/4XW1/5XW1/6
Power (kW)1.12347.511
Voltage (V)380
Input Line SystemThree-Phase Five-Wire
Maximum Spray Flow Rate (t/h)0.30.60.91.2524
Inlet Size0.5"/DN150.5"/DN150.5"/DN151"/DN251.5"/DN402"/DN50
Outlet Size1/8"-11/8"-11/8"-21/8"-31/4"-21/2"-2
Dimensions (mm)1400×700×1600
Water SupplySub-Water Tank Automatic Control
Signal4-20mA Current Signal
Control SystemPLC Programmable Control System
CCJ/A Type Wet Dust Remover Assembly, continued (13 rows)
Model/SpecificationsECMC-11ECMC-15ECMC-20ECMC-30ECMC-40
ECMC Series Top Dust RemoverAir Volume ( m^3/h )720-9901040-14201500-21002100-29002800-3800
Fan Power (kW)2.22.2445.5
Filter Bag Specification (mm)φ140x1000φ140x1000φ140x1500φ140x1500φ140x2000
Number of Filter Bags2536364949
Filtration Area ( m2 )1115.823.732.343.1
Pulse Valve Specification1.0"
Number of Pulse Valves56677
Filter Bag MaterialCoated Polyester Fiber
Cleaning MethodPulse Cleaning
Equipment Dimensions (mm)Length (mm)11001300130014701470
Width (mm)11001300130014701470
Height (mm)14001400190019002400
Purification Efficiency %>99.5
CCJ/A Type Wet Dust Remover Assembly, continued (12 rows)
Model/SpecificationsETMC I-8ETMC I-12ETMC I-16ETMC II-24ETMC III-36ETMC IV-48ETMC IV-60ETMC IV-72
Filter Cartridge Main Unit SpecificationsAir Volume (m3/h)2250-45003380-67604500-90006760-1352010150-2030013530-2706016920-3384020300-40600
Fan Power (kW)5.57.5111522303745
Number of Filter Cartridges812162436486072
Filtration Area (m2)75.2112.8150.4225.6338.4451.2564676.8
Pulse Valve Specification1.0"
Number of Pulse Valves4681218243036
Filter Bag MateriaCoated Polyester Fiber
Cleaning MethodPulse Cleaning
Equipment Dimensions (mm)Length (mm)11001100110022003300440055006600
Width (mm)18601860186018601860186018601860
Height (mm)29003400390034003400340034003400
Purification Efficiency %>99.5
Parameter boundary

Standard-model catalogue figures. Actual capacity, power draw and wear life shift with ore properties, feed gradation and circuit conditions. Use them to shortlist, then confirm the duty by testwork, flowsheet calculation and a written confirmation from the manufacturer.

What decides the selection

Define the total airflow required and the dust loading of each airstream to be extracted. Confirm the dust characteristics: particle size distribution, moisture content and whether the material is sticky or abrasive. Specify the available water quality and disposal route for the slurry. Determine the layout constraints that dictate duct positions and the space available for the assembly, including the ventilator footprint.

  • Air volume
  • Inlet dust concentration
  • Particle size
  • Temperature and humidity
  • Explosibility
  • Emission limit
  • Filtration velocity and pressure drop
  • Cleaning method
  • Water availability

All dust collection equipment

Other dust collection machines

30+
years in mining equipment
1,000+
equipment models
70+
ore types processed
100+
countries reached

ISO 9001 / ISO 14001 / ISO 45001 / ISO 9712 / CE / CSA W47.1 / CNAS accredited laboratory

Send the duty, get a sized proposal